Specifications
(23 +/- 5 deg C)
DCA 0-40A 10mA +/- 1.0% +/- 2dgts
DCA 0-150A 100mA +/- 1.0% +/-2 dgts
DCA 150-200A 100mA -2.2% +/- 2dgts
ACA 0-40A 10mA +/- 1.0% +/- 3 dgts
ACA 0-150A 100mA +/- 1.0% +/- 3 dgts
ACA 150-200A 100mA -2.2% +/- 3dgts
DCV 0-400V 0.1 V +/- 1.0% +/- 2dgts
ACV 0-400V 0.1 V +/- 1.0% +/- 2 dgts
0
Ohm-400 Ohm 0.1 Ohm +/- 1.0% +/-2dgts beep if < 40 Ohm (Approx.)
Hz 0-1000KHz 0.1-100 +/- 0.5% +/- 2dgts 1V
sensitivity
Auto Range
General Specification
General Specification
Conductor Size: 23mm max. (approx.)
Battery Type: two 1.5V SUM-3
Display: 3 3/4 LCD with 40 seg. bargraph
Range Selection: manual
Overload Indication: left most digit blinks
Power Consumption: 10 mA (approx.)
Low battery Indication:
Sampling Time: 2 times/sec. (display)
20 times/sec. (bargraph)
Operating Temperature: -10 deg C to 50 deg C
Operating Humidity: less than 85% relative
Altitude : up to 2000M
Storage Temperature: -20 to 60 deg C.
Storage Humidity: less than 75% relative
Dimension: 183mm (L) x 63.6mm (W) x 35.6mm (H)
7.2"" (L) x 2.5"" (W) x 1.4"" (H)
Weight: 190g (battery included)
Accessories: Carrying bag x 1
Users manual x 1
1.5V battery x 2