AC/DC Current clamp meter ( DCM-042)

TECPEL DCM-042 a high high resolution AC/DC clamp meter. With the resolution of 0.l. This current clamp meter is a great tool for PWM
trouble shootingand in noisy environment measurment. Inrush current(100mS) mode is very helpful for measuring start current to check
motors, lighting equipment and etc.,


  • 600A DC/AC True RMS Industrial Clamp Meter
  • Maximum reading of 9999
  • ACA/DCA measurement up to 600.0A
  • Inrush current (100mS) mode, for measuring start current for motors, lighting, etc.
  • Good for PWM trouble shooting and in Noisy environment measurement
  • Improved low current measurement accuracy
  • Temperature Compensation Current sensor
  • HOLD/PEAK HOLD, MAX/MIN, A-Hz and V-Hz function
  • Auto shut-off maximizes battery life
  • Large, backlit display easy to see
  • Dimensions of conductor: O35mm
  • EN61010-1 Approval. Over-Voltage Category CAT III 1000V


Specifications :


AC/DC Current Clamp meter ( DCM-042)
Specifications:

AC Current (accuracy: at the center of CT)

Range: 0 to 600.0A

Accuracy: ±(2.0%rdg+5dgts) on 20Hz to 100Hz

±(6.0%rdg+5dgts) on 100Hz to 400Hz

Resolution: 0.1A

AC Voltage

Range: 0 to 600.0V

Resolution: 0.1V

Accuracy: ±(1.0%rdg+5dgts) on 20 to 100Hz

±(6.0%rdg+5dgts) on 100 to 400Hz

Input impedance: 1M?

DC Current (accuracy: at the center of CT)

Range: 0 to 600.0A

Accuracy: ±(2.0%rdg+5dgts)

Resolution: 0.1A

DC Voltage

Range: 0 to 600.0V

Resolution: 0.1V

Accuracy: ±(1.0%rdg+5dgts)

Input impedance: 1M?

Resistance (Autorange)

Range: 0 to 999.9?, 1000 to 9999?

Accuracy: ±(1.5%rdg+5dgts)

Resolution: 0.1?/1?

Frequency

Range: 20 to 400.0Hz

Resolution: 0.1Hz

Sensitivity: 5Vrms TTL signal,

5A @20 to 100Hz, 10A @100 to 400Hz

Accuracy: ±(0.5%rdg + 5dgts)

Diode Test

Accuracy: ±(3.0%rdg+3dgts)

Resolution: 0.001V

Test current: 0.2mA

Test Voltage: <3.0V

Continuity

Audible indication: less than 30?

Capacitance

Range: 0 to 999.9µF

Resolution: 0.1µF

Accuracy: ±(5.0%rdg + 10dgts)

Temperature (K-Type Thermocouple)

Range: -40°C to 1200°C, -40°F to 2200°F

Accuracy: ±(0.5%rdg+1°C)

±(0.5%rdg+2°F), (not including thermocouple error)

Resolution: 0.1°C on -40°C to 999.9°C

1°C on 1000°C to 1200°C

0.1°F on -40°F to 999.9°F

1°F on 1000°F to 2200°F
TECPEL CO., LTD.
Digital Clamp-on Meter  DCM-042