TECPEL CO., LTD.


LCR-615-100KHZ- 40000 Count   with high accuracy of 0.1%
handheld-RLC meter

With its advanced impedance test technology, TECPEL has launched  this new LCR-
615 handheld LCR meters. This  LCR-615 currently possess the most powerful
functions and outstanding performance in this industry comparable with bench LCR
meters. Meanwhile it is the achievement of TECPEL after years of efforts and
research in the passive-component testing field. The LCR-615 apply the ultra-low
power consumption design and high density SMD assembly techniques and can
simultaneously display primary and secondary parameters on a LCD display with
backlight. The dual-color shell is gorgeously once shaped; and functions are easy to
operate. The test frequency is up to 100 kHz, the readings of primary parameter
40,000 counts and the resolution of dissipation factor 0.0,001. Accurate and
convenient measurements of passive-components can be achieved in different
occasions for a long time. In order to meet different market demand, multiple signal
level and DCR test function are increased on  this LCR-615. The test accuracy can
reach 0.1%. With USB interface, This LCR-615  series can conveniently
communicate with a PC and be remotely controlled by a PC. In order to satisfy the
increasing test requirements for SMD and balance the different needs for
performance and price, two types of 4-terminal Kelvin test tweezers are equipped with
accessoires  for users’ choice.






































































LCR-615   Main Features:

■ Max. Basic accuracy: 0.1%

■ Maximum test signal frequency : 100kHz


Features

■ Max. Basic accuracy: 0.1%

■ Maximum test signal frequency : 100kHz

■ Selectable test signal level

■ With DCR function

■ Enhanced protection capability of input terminal impact

■ 40000 counts for primary parameter, D/Q resolution 0.0001

■ Typical ultra-low consumption: 25mA

■ Innovatively compatible terminal configuration: 5-terminal test slot and 3-terminal banana jack

■ Intellectualized auto LCR function

■ AC test speed up to 4 meas/sec (DCR: 3 meas/sec), fast automatic range switch design

■ Constant 100Ω output impedance

■ Percentage display and 4-tolerance comparator: 1/5/10/20%

■ Battery charge in startup & shutdown

■ Test terminal protection function

■ Data-hold, Max./Min./Average value recording

■ Real-time function configuration selection and working condition hold capacity

■ Standard configuration Mini – USB communication interface and SCPI command set

■ Free FastAccess PC communication software on our website

■ Gorgeous dual-color cast shell



Specifications                                                                                 
Model  LCR-615                                                                                 
Function                                                                                          
Test Parameter                                                                                    
Primary parameters: L / C / R / Z/ DCR                                                               
Secondary parameters: D / Q / R /θ/ ESR                                                      
Equivalent Circuit Series and Parallel                                                               
Parameter and                                                                                 
Equivalent Mode Hold, Auto                                                                        
Ranging Mode Auto                                                                        
Measurement                                                                                 
Terminals 3-terminal, 5-terminal                                                               
Measuring Speed 4meas/sec, 1.5meas/sec                                                      
DCR Measuring                                                                                 
Speed ------ 3meas/sec                                                                        
Calibration Function Open, short                                                               
Comparator Function   1%, 5%, 10%, 20%                                                        
Input fuse 0.1A / 250V                                                                        
Interface Mini-USB (virtual serial port)                                                               
Test signal                                                                                 
Test Frequency                                                                                 
100Hz, 120Hz, 1kHz, 10kHz, 100kHz                                                               
Test Level  0.3 Vrms, 0.6 Vrms, 1 Vrms                                                               
Output Resistance 100Ω                                                                        
Display                                                                                          
Display LCD Primary-Secondary dual display, with backlight (LCR-
615)                           
Reading Max. Primary parameters: 40,000 digits, secondary parameters D/Q
Minimum resolution: 0.0001
Basic accuracy   0.1%                                                                        
Measuring Range                                                                                 
L  0.000μH - 1000.0H                                                                        
C   0.000pF - 20.000mF                                                                        
Z/R 0.0000Ω- 10.000MΩ                                                                        
DCR - 0.0000Ω- 20.000MΩ                                                                        
ESR 0.0000Ω- 999.9Ω                                                                        
D 0.0000 - 9.999                                                                                 
Q 0.0000 - 9999                                                                                 
θ 0.00°- ±180.0°                                                                                 
Power Requirements                                                                        
8.4V Ni-MH 200mAH rechargeable battery (LCR-615)                                             
AC power adapter Input: 110V/50Hz, Output: 12V-15V(100Ω
Load)                                    
Standby Currant Max. 11μA                                                                        
Battery life 16 hours (typical) , new alkaline battery, with backlight off                           
Auto power off 5min, 15min, 30min, 60min, OFF available; Factory Default :
5min                  
Low voltage indicator : When battery voltage drops below 6.8V, low voltage indicator
turns on.         


Ordering information:

LCR-615    Handheld LCR meter 100KHz   0.1% Accuracy


Minimum Order: Negotiable
TEL: 886-2-27375866
FAX: 886-2-27373343
E-mail:  sales@tecpel.net
http://www.tecpel.net