TECPEL CO., LTD.


LCR-614-10KHZ- 40000 Count with high accuracy of 0.25%  
handheld-RLC meter


With its advanced impedance test technology, TECPEL  has launched New handheld
LCR meters. This series currently possess the most powerful functions and
outstanding performance in this industry comparable with bench LCR meters.
Meanwhile it is the achievement of  TECPEL  after years of efforts and research in
the passive-component testing field. This LCR-614  apply the ultra-low power
consumption design and high density SMD assembly techniques and can
simultaneously display primary and secondary parameters on a LCD display with
backlight. The dual-color shell is gorgeously once shaped; and functions are easy to
operate. The test frequency is up to 10 kHz, the readings of primary parameter
40,000 counts and the resolution of dissipation factor 0.0,001. Accurate and
convenient measurements of passive-components can be achieved in different
occasions for a long time. In order to meet different market demand, multiple signal
level   are increased on  LCR-614. The test accuracy can reach 0.25%. With USB
interface,  This LCR-614 can conveniently communicate with a PC and be remotely
controlled by a PC. In order to satisfy the increasing test requirements for SMD and
balance the different needs for performance and price, two types of 4-terminal Kelvin
test tweezers  are  equipped with accessories for users'  choice.

































































LCR-614  Specifications:

■ Max. Basic accuracy: 0.25%

■ Maximum test signal frequency : 10kHz

■ Selectable test signal level

■ Enhanced protection capability of input terminal impact

■ 40000 counts for primary parameter, D/Q resolution 0.0001

■ Typical ultra-low consumption: 25mA

■ Innovatively compatible terminal configuration: 5-terminal test slot and 3-terminal banana jack

■ Intellectualized auto LCR function

■ AC test speed up to 4 meas/sec (DCR: 3 meas/sec), fast automatic range switch design

■ Constant 100Ω output impedance

■ Percentage display and 4-tolerance comparator: 1/5/10/20%

■ Battery charge in startup & shutdown

■ Test terminal protection function

■ Data-hold, Max./Min./Average value recording

■ Real-time function configuration selection and working condition hold capacity

■ Standard configuration Mini – USB communication interface and SCPI command set

■ Free FastAccess PC communication software on our website

■ Gorgeous dual-color cast shell

Brief Introduction


Model LCR-614                                                                        
Function                                                                                 
Test Parameter Primary parameters: L / C / R / Z                                             
Secondary parameters: D / Q / R /θ/ ESR                                                      
                                                                               
Equivalent Circuit Series and Parallel                                                      
Parameter and                                                                        
Equivalent Mode Hold, Auto                                                               
Ranging Mode Auto                                                                        
Measurement                                                                        
Terminals 3-terminal, 5-terminal                                                      
Measuring Speed 4meas/sec, 1.5meas/sec                                             
                                                                               
Calibration Function Open, short                                                      
Comparator Function   1%, 5%, 10%, 20%                                             
Input fuse 0.1A / 250V                                                               
Interface Mini-USB (virtual serial port)                                                      
Test signal                                                                        
Test Frequency                                                                        
100Hz, 120Hz, 1kHz, 10kHz,                                                               
                                                                               
Test Level 0.6Vrms                                                                          
Output Resistance 100Ω                                                               
Display                                                                                 
Display LCD Primary-Secondary dual display,                                               
Reading Max. Primary parameters: 40,000 digits, secondary parameters D/Q Minimum resolution:
0.0001
Basic accuracy 0.25%                                                                 
Measuring Range                                                                        
L: 0.00μH - 1000.0H                                                                 
C  0.00pF - 20.000mF                                                                 
Z/R 0.0000Ω- 10.000MΩ                                                               
ESR 0.0000Ω- 999.9Ω                                                               
D 0.0000 - 9.999                                                                        
Q 0.0000 - 9999                                                                        
θ 0.00°- ±180.0°                                                                        
Power Requirements                                                                        
Battery model   9V alkaline battery                                                      
AC power adapter Input: 110V/50Hz, Output: 12V-15V(100Ω Load)                           
Standby Current Max.2μA                                                                
Battery life 16 hours (typical) , new alkaline battery,                                      
Auto power off 5min, 15min, 30min, 60min, OFF available; Factory Default : 5min                  
Low voltage indicator :                                                               
When battery voltage drops below 6.8V, low voltage indicator turns on.                           
Certificate:

CE
Contact Detail


Certificate: CE

Ordering information:

LCR-614    Handheld LCR meter 10KHz   0.25% Accuracy


Minimum Order: Negotiable
TEL: 886-2-27375866
FAX: 886-2-27373343
E-mail:  sales@tecpel.net
http://www.tecpel.net
LCR-614-10KHZ- 40000 Count with high accuracy of 0.25%  handheld-RLC meter
LCR-614-10KHZ- 40000 Count with high accuracy of 0.25%  handheld-RLC meter all