Product ID: LCR-612
LCR Meter
Model: LCR612
20000 Counts LCR Meter
Dual Display Auto-Ranging
Features:
- Basic accuracy:
- 0.5% for Resistance ;
0.7% for Inductance and Capacitance
- Dual Displays provide quick tested results readouts,
- with L.C.R. Display values up to 19999 counts and
- Q.D.R. display values up to 9999 counts (Auto range)
- Excellent resolutions:
- Resistance up to 0.001W,
- Inductance Capacitance up to 0.1uH/0.1pF
- Provided up to 4 testing parameters:
- Ls+(Q,D,Rs), Lp+(Q,D,Rp) ; Cs+(Q,D,Rs),
Cp+(Q,D,Rp)
to conserve battery life for longer use.
To inform that the fuse is open or damaged.
Provide optical standard RS-232. cable
- External DC Adapter functions:
- Use of a DC adapter (optiona) can also serve to disable
Auto Power Off function.
- The test lead TL-06 (Option) is
specially designed for measuring SMD
(Surface mount device) resistor, capacitor and inductor
Specifications:
Display:
L\C\R 4 digits, maximum reading of 19999.
Q\D\R 4 digits, maximum reading of 9999. (Auto range).
Capacitance:
8 Ranges 1KHz Accuracy 120Hz Accuracy
20 mF Nil +/-(5.0 %+5 Counts)/(DF<0.1)
2000 uF +/-(5.0 %+5counts)/(DF<0.1) +/-(1.0 %+5 counts)/(DF<0.1)
200 uF +/-(1.0 %+5 counts)/(DF<0.5) +/-(0.7 %+3counts)/(DF<0.5)
20 uF +/-(0.7 %+3 counts)/(DF<0.5) +/-(0.7 %+3 counts)/(DF<0.5)
2000 nF +/-(0.7 %+3 counts)/(DF<0.5) +/-(0.7 %+3 counts)/(DF<0.5)
200 nF +/-(0.7 %+3 counts)/(DF<0.5) +/-(0.7 %+5 counts)/(DF<0.5)
20 nF +/-(0.7 %+5 counts)/(DF<0.5) +/-(1.0 %+5 counts)/(DF<0.1)
2000 pF +/-(1.0 %+5 counts)/(DF<0.1) Nil
Resolution up to 0.1 pF
Inductance Ranges: (DF < 0.5)
8 Ranges 1KHz Accuracy 120Hz Accuracy
10000 H Nil No specified
2000 H No specified +/-(1.0%+5 counts)
200 H +/-(1.0%+5 counts) +/-(0.7% + 5 counts)
20 H +/-(0.7 %+5 counts) +/-(0.7%+5 counts)
2000 mH +/-(0.7 %+5 counts) +/-(0.7%+5 counts)
200 mH +/-(0.7 %+5 counts) +/-(1.0%+5 counts)
20 mH +/-(1.2%+5 counts) +/-(2.0%+5 counts)
2000 uH +/-(2.0%+5 counts) Nil
Resolution up to 0.1uH
Resistance Ranges:
7 Ranges 1KHz/ 120 Hz Accuracy
10 M Ohm +/-( 2.0% +8 counts)
2000 K Ohm +/- (0.5% + 5 counts)
200 K Ohm +/- (0.5% + 3 counts )
20 K Ohm +/- ( 0.5% + 3 counts)
2000 K Ohm +/- ( 0.5% + 5 counts)
200 K Ohm +/- ( 0.8% + 5 counts)
20 Ohm +/- ( 1.2% + 8 counts)
Resolution up to 0.001 Ohm
Parameter Measurement:
Ls+(Q,D,Rs), Lp+(Q,D,Rp); Cs+(Q,D,Rs), Cp+(Q,D,Rp)
Overload: "OL" is display.
Range Mode: . Auto and Manual
Test Frequency: 1KHz and 120Hz.
Measurement rate: Approx. 1 time per second, nominal.
General
Power Requirement:
(1) Single Standard 9V battery (NEDA 1604, IEC 6F22 006P)
(2). External DC Adapter 12Vmim to 15Vmax / 50mA. (Optional)
Auto Power Off: The meter key switch inactive for more than 5 minutes, press power
key to resume operation.
Overload Protection 0.1A/250V fast below fuse.
Ambient Operating Ranges 0 deg C to 50 deg C(-32 deg F to 122 deg F) < 80% R.H.
Sotragne Temperature -20 deg C to 60 deg C(-4 deg F to 140 deg F) < 70 % R.H.
Dimensions:
192mm(H) x 91mm(W) x 52.5mm(D).
Weight:
365g. (including accessories)
Accessories:
Comes complete with leads, battery and owners manual.
LCR Test Lead
Model : TL-06 (Option)
Features:
- TL-06 is specially designed for measuring SMD (Surface mount device)
- resistor, capacitor and inductor
- Suitable for any multimeter with banana terminal input.
Ordering Information:
LCR-612 LCR meter
TL-06 SMD Test Lead
Minimum Order: Negotiable
TEL: 886-2-27375866
FAX: 886-2-27373343
E-mail: sales@tecpel.net
http://www.tecpel.net
TECPEL CO., LTD.
TL-06 Optional Test lead
for SMD components