Product ID: LCR-200
Precision LCR Instrument
FEATURES :
- Measurement Parameters :
- Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and θ.
- Test conditions :
- 100MHz , 120Hz , 1KHz , 10KHz , 100KHz , 200KHz
- Basic Accuracy 0.1% ;
- Test Voltage:
- 1Vrms , 250mVrms , 50mVrms , 1Vdc(DCR only)
- DMM Functionalities
- Dual LCD Display with LED backlit
- Open/Short Calibration
- Remote Binning capacity
- Auto range/ Range hold selection
- RS-232 Interface
LCR 200 Precision LCR Instrument
SPECIFICATIONS
Test Condition :
Frequency : 100Hz/120Hz/1KHz/10KHz/100KHz/200KHz
Level : 1V rms/250mVrms/50mVrms/1Vdc(DCR only)
Measurement Parameters : Z , Ls , Lp , Cs , Cp , DCR , ESR , D , Q , and θ.
Basic Accuracy : 0.1%
--------------------------------------------------------------------------------
PRIMARY PARAMETERS DISPLAY
Z AC Impedance
DCR DC Resistance
Ls Serial Inductance
Lp Parallel Inductance
Cs Serial Capacitance
Cp Parallel Capacitance
--------------------------------------------------------------------------------
SECONDARY PARAMETERS DISPLAY
θ Angle Impedance
ESR Equivalent Series Resistance
D Dissipation Factor
Q Quality Factor
COMBINATIONS OF Display
Serial Mode Z-θ, Cs-D, Cs-Q, Cs-ESR, Ls-D, Ls-Q, Ls-ESR
Parallel Mode Cp-D, Cp-Q, Lp-D, Lp-Q
--------------------------------------------------------------------------------
MEASUREMENT RANGE
Parameter Range
z 0.000 Ohm to 500.0 Ohm
L 0.030 uH to 9999 H
C 0.003 uH to 9999 H
DCR 0.000 Ohm to 500.0 M Ohm
ESR 0.000 Ohm to 9999 Ohm
D 0.000 to 9999
Q 0.000 to 9999
θ -180.0 degree to 180 degree
V 0.000mV to +/- 600.0V
ESR 0.000 Ohm to 9999 Ohm
D 0.000 to 9999
Q 0.000 to 9999
θ -180.0 degree to 180 degree
V 0.000mV to +/- 600.0V
I 0.000mA to +/- 2.000A
--------------------------------------------------------------------------------
DC VOLTAGE MEASUREMENT
Range 2V, 20V, 200V and 600V
Resolution 1mV, 10mV, 100mV, 1V
Accuracy +/- (0.4% +3 digits)
input Impedance 1 M Ohm
AC CURRENT MEASUREMENT
Range 2A, 0.2A, 20mA and 2mA
Resolution 1mA, 10mA, 100mA, 1A
Accuracy +/-(0.8% +5 digits) @ 40 Hz ~ 1 kHz
Input Impedance 1M ohm
AC CURRENT MEASUREMENT ( True RMS)
Range 2A, 0.2A, 20mA and 2mA
Resolution 1mA, 10mA, 100mA, 1A
Accuracy +/-(0.8% +5 digits) @ 40 Hz ~ 1 kHz
Current Shunt 0.1 Ohm@ current > 20mA/ 10 Ohm@ current </= 20mA
CONTINUITY CHECK
Continuity Thresh hold 50 Ohm (Approximately)
Continuity Indicator Tone Buzzer
Input Protection 600 Ohm (max)
DIODE TEST MEASUREMENT
Test Current 2.5mA ( Typical)
Open Circuit Voltage 5.0V DC (NOMINAL)
Input Protection 600V (max)
DIODE TEST MEASUREMENT
Power source AC 110/ 220V +/- 10% ; 50 / 60 Hz
Operating Temp 0 to 40 deg C (Operating) ; < 85 % RH
Storage Temp -20 deg to 70 deg C
GENEARL
Dimensions: 300 mm x 220 mm x 150 mm ( 11.8" x 8.7" x 5.9 ") (Dx W x H)
Weight 4.5 kgs
Standard Accessories (1). TL09C Kelvin Clips x 1 pc ( 2) Test Leads x 1 pc Power Cord x 1 ;
Instruction Manaul x 1
Optional Accessories (3) TL09A SMD test Probe ( 4) TL 09B Component Fixture
Certificate: CE
Ordering information:
LCR-200 LCR precision Instrument
Minimum Order: Negotiable
TEL: 886-2-27375866
FAX: 886-2-27373343
E-mail: sales@tecpel.net
http://www.tecpel.net
TECPEL CO., LTD.
Optional Accessory