LCD Digital Anemometer
Function:  
ON/OFF, H/T, °F/°C, 10 Memories, Air Velocity Unit, AVG (Multipoint),
Air Flow Vlume Measurement, AVG/MAX/MIN  Reading.






Features:
  • Instant Display of the air Velocity and temperature
  • Maximum , Minimum and average Value Calculation
  • Easy Air flow Volume calculation (CMF/CMM)
  • 10 Memories Data Storage/Recalling/Clearing
  • Data HOLD/TEST function
  • Low Battery Indication
  • One Hour Auto Shut off function



























SPECIFICATION:

MEASUREMENT RANGE: -50°C ~ +70°C OR –58°F ~ +158°F
RESOLUTION : ± 0.1° FOR WHOLE RANGE
ACCURACY : ±0.5°C FOR 0°C ~ +50°C OR ±0.9°F FOR +32°F ~ +122°F, OTHERWISE ±1°C OR 1.8°
F
SENSING TIME: 1 SECOND

BATTERY: 3 X 1.5 VOLTS “AAA” SIZE OR EQUIVALENT  



AIR VELOCITY MEASUREMENT :
MEASUREMENT RANGE RESOLUTION
0.0 TO 45.0 m/s (METER PER SECOND)  0.1
0.0 TO 140.0 km/hr (KILOMETERS PER HOUR) 0.1
0.0 TO 100.0 mph (MILE PER HOUR) 0.1
0 TO 8800 ft/min (FEET PER MINUTE) 10
0.0 TO 88.0 knots (NAUTICAL MILES PER HOUR) 0.1
ACCURACY: ± (0.3 ± 2% Reading) for 2 m/s or above.




INSTALLATION:
UNPACK THE ANEMOMETER WITH CARE.
OPEN THE BATTERY DOOR. THEN INSTALL THREE 1.5 VOLTS “AAA” SIZE OR EQUIVALENT
BATTERY INTO THE BATTERY COMPARTMENT. AND CLOSE THE BATTERY DOOR.
REPLACE NEW BATTERY WHEN THE LOW BATTERY INDICATOR APPEARS ON THE SCREEN.




OPERATION:
ON/OFF
Press “ON/OFF” FOR ON/OFF SWITCHING. FULL DISPLAY SHOWS FOR A WHILE. THE UPPER
DISPLAY SHOWS THE VELOCITY (DEFAULT AS m/s) VELO SIGN APPEAR, WHILE THE LOWER
DISPLAY SHOWS THE TEMPERATURE (DEFAULT AS °F) MEASURED.

ONE HOUR AUTO SHUT OFF FUNCTION & CANCELLATION
THIS PRODUCT WILL TURN OFF AUTOMATICALLY AFTER ONE HOUR.
TO DISABLE THIS FUNCTION, PRESS “ON/OFF” AND “H/T” TOGETHER TO TURN ON THE UNIT
EACH TIME. THE PRODUCT WILL KEEP WORKING UNTIL BEING SHUT OFF BY USERS.

UNIT
THE UNIT IS DEFAULT IN ft/min AS MEASUREMENT UNIT FOR AIR VELOCITY. USER CAN PRESS
THIS BUTTON TO INTERCHANGE THE AIRFLOW VELOCITY UNIT AS THE FOLLOWING:
ft/min > mph > m/s > km/hr > knots.

HOLD/TEST
PRESS THE BUTTON TO FREEZE THE READING FOR RECORDING (BOTH VELOCITY &
TEMPERATURE), HOLD SIGN APPEARS.
PRESS AGAIN THE UNIT WILL RESTORE TO REAL TIME MODE.

°F/°C
PRESS TO SWITCH THE READING BETWEEN °C AND °F AS TEMPERATURE UNIT.

AVG/MAX/MIN READING FOR CONTINUE MOVING AVERAGE MEASUREMENT (SINGLE POINT)  
a)  PRESS ONCE THE UNIT WILL SHOW THE CONTINUE MOVING AVERAGE MEASUREMENT OF
VELOCITY (AVG), MAXIMUM MEASUREMENT (MAX) AND MINIMUM MEASUREMENT (MIN) AS
FOLLOWING:
AVG > MAX(BOTH TEMP & VELOCITY) > MIN(BOTH TEMP & VELOCITY) > REAL TIME READING  
b)  RELEVANT SIGN APPEARS ON THE DISPLAY AND READING UPDATE PER SECONDS.  
c)  TO CLEAR VALUE, PRESS AND HOLD THE KEY FOR 3 SECONDS, 2 SUCCESSIVE BEEPS
SOUND IS
GIVEN OUT.

AVG (MULTI POINT)
a) HOLD THE UNIT IN POSITION, PRESS THE “HOLD” BUTTON TO FREEZE THE READING (BOTH
VELOCITY AND TEMPERATURE).
b) THEN PRESS “MEM” BUTTON TO SAVE THE READING. (A SINGLE BEEP IS GIVEN OUT FOR
EVERY SUCCESSFUL SAVING). MEM 1 DISPLAYS REPRESENTING ONE READING IS SAVED.
c) REPEAT STEP (a) – (b) TO SAVE ANOTHER READING, MEM 12 DISPLAYS REPRESENTING 2
READINGS ARE SAVED.  
d) CONTINUE TO DO SO UP TO 10 SETS OF READING CAN BE SAVED.
e) ONCE ALL MEASUREMENT HAVE BEEN SAVED, PRESS “AVG (MULTI POINT)” BUTTON, THE
UNIT WILL DISPLAY THE AVERAGE AIR VELOCITY FROM MEMORY AND AVG SIGN APPEARS.

MEM (MEMORY RECALLING)
a) Press THE “MEM” BUTTON, ALL SAVED READING (BOTH TEMPERATURE & VELOCITY) WILL BE
SHOWN, STARTING FROM THE 1ST READING (i.e. MEM 1) TO THE 10TH READING (i.e. MEM 10).  
b) PRESS AND HOLD THE “MEM” BUTTON FOR 3 SECONDS TO CLEAR ALL SAVED READINGS.

AIR FLOW VOLUME MEASUREMENT
(i)  SINGLE POINT MEASUREMENT
a) DETERMINE THE FREE AREA OF THE AIR SOURCE.
b)  PRESS “AIR FLOW” BUTTON FOR 3 SECONDS TO DEFINE FREE AREA, DISPLAYS SHOWS
AREA SIGN AND FIRST DIGIT OF 1.111 sq feet FLASHES.
c) PRESS “HOLD” BUTTON TO INCREASE NUMBER OF THE FLASHING DIGIT.
d)  PRESS “AVG (MULTI POINT)” BUTTON TO MOVE TO THE NEXT DIGIT.
e) PRESS THE “AIR FLOW” BUTTON, THE DEFINED FREE AREA IS SAVED AND THE UNIT IS NOW
READY TO MEASURE AIR FLOW (CFM) AND FLOW SIGN APPEARS. VALUE SHOWS ON THE
UPPER DISPLAY.

(i)  AVERAGE FOR MULTI POINT MEASUREMENT
PRESS AND HOLD THE “AVG (MULTI POINT)” BUTTON FOR 3 SECONDS TO CLEAR CURRENT
AVERAGE READINGS IN THE VELOCITY/FPM MODE.

a) REPEAT (a) TO (e) IN SECTION (G) TO DETERMINE ALL MULTI-POINT AVERAGE READING.
b)  PRESS “AIR FLOW” BUTTON FOR 3 SECONDS AND UNIT ENTERS TO THE FREE AREA
SETTING.
c) REPEAT STEP (a) TO (e) IN SECTION (Ii) TO DEFAULT FREE AREA SETTING.
d)  PRESS “AIR FLOW” BUTTON TO CONFIRM AND UNIT ENTERS TO THE CFM MODE. THE UNIT
DISPLAY AVERAGE AIR FLOW READING AND NUMBER OF POINTS MEASURED. VALUE SHOWS
ON THE UPPER DISPLAY.






PRECAUTIONS
REMOVE THE BATTERY FROM THE BATTERY COMPARTMENT IF THE ANEMOMETER WILL NOT
BE USED FOR LONG DURATION OF TIME OR DURING STORAGE.
THE THERMOMETER CANNOT BE USED OR PUT INSIDE ANY OVEN OR MICROWAVE.







Ordering Information:
AVM-715  Anemometer


Minimum Order: Negotiable
TEL: 886-2-27375866
FAX: 886-2-27373343
E-mail:  sales@tecpel.net
http://www.tecpel.net
TECPEL CO., LTD.
With Carrying Case